Customization: | Available |
---|---|
Type: | Smoke Detectors |
Anti-theft Alarm System Approach: | Active |
Still deciding? Get samples of US$ 12.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC 220V main power DC 9V backup battery with wired and RF
interconnection photoelectric smoke alarm
Technical Specifications:
Power Source | AC 220V-AC240V, DC 9Vbattery backup | Alarm Volume | >85dB(A) @ 3 meters |
AC Quiescent Current | < 100mA | Low Voltage Threshold | ≤7.5V |
AC Alarm Current | < 100mA | Hush Time | 8minutes |
DC Quiescent Current | < 10uA | Product Service Life | >10 years |
DC Alarm Current | < 28mA | Humidity Range | < 93% relative humidity (RH) |
Alarm Sensitivity | 0.10-0.16dB/m | Temperature Range | 0ºC to 40ºC |
Comply With Standard | EN14604:2005/AC:2008 | Size | 140mm in diameter x 45.1mm depth |
Sound Pattern | (BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the RED LED flash, repeat this alarm pattern) |
Standby mode | After the product is installed, if the smoke alarm device operate properly, the red LED flashes once every 40 seconds |
Local alarming mode | When the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with pulsating alarm until the smoke is disappeared |
Interconnection alarming mode | When the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the alarm will send local alarm signal, other interconnection alarms will send alarm signals. The wired interconnection alarms will go into interconnection alarm mode: BI - BI - pause 1.2s, with the red LED flashes, this alarm pattern is repeated |
Low battery mode | When the battery voltage below threshold, the red LED will flash once every 40 seconds with a sound of "chrip" |
Fault mode | If the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 40 seconds |
Silence mode | Press the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds |
No disturb mode | When the alarm device is in low battery mode, in order to avoid disturbing you at night, please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 40 seconds during No disturb mode |
Test mode | Test the unit to ensure proper operation by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is released |
NOTE | WEEKLY TESTINGIS REQUIRED. |
>1< | Select one of smoke alarms as the MASTER unit. Treat other units as SLAVE units. |
>2< | Press the test button on the MASTER unit three times within two seconds, the red LED will flash quickly, the unit is now in sending radio signal mode. This mode will last for 48 seconds. |
>3< | While the MASTER unit is in sending radio signal mode, press the test button on any SLAVE unit three times within two seconds, the SLAVE unit learns this signal and completes the pairing after a sound "beep" with light flash once |
>4< | Repeat the above steps on all other SLAVE units |
Clear wireless connection function | Press the test button on any SLAVE unit three times within two seconds, the red LED will flash quickly, then press and hold the test button again until the red light goes out the first time and release the button immediately, the red LED will flash slowly, at this time, press the test button again, the SLAVE unit will beep 3 times, which means that the SLAVE unit clears wireless connected successfully. |