  • BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
  • BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
  • BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
  • BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
  • BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
  • BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
Find Similar Products

Basic Info.

Model NO.
THS385D-HR
Working Mode
Passive
Certification
CE, ISO, RoHS, CCC, Bsi
Application
Indoor
Working Principle
Electro-Optical Type
Transmission Mode
Wireless
Alarm Volume (within 1m)
≥90dB
Receive Frequency
433.92MHz
Battery Life
at Least Ten Years Battery Life
RF Function
Radio Frequency 433MHz
Wireless Interconnection Function
The Maximum Number of Connections Is up to 40 Devi
Certificate
CE, Bsi, Ukca, RoHS, Reach, ISO9001, BSCI
Product Features
Rapidly Detect Heat Alarm
Transport Package
Carton
Specification
Φ 120*46.5mm
Trademark
JBE
Origin
Hangzhou, China
Production Capacity
100000 Piece/Month

Product Description

 
BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
Rapidly detect heat alarm
Technical Parameters:
Operating voltage DC3V(CR17450x1)
Standby current <10pA
Emitter current <25mA
Alarm current <35mA
Communication firequency 433MHz
Transmission distance >100m@ Visual distance
work environment 0~40°C<93%RHNon-condensate
Environmentalstandards RoHs,REACH
Product Size p120*46.5mm
Product net weight 111g
BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm
Product Overview
          The unit is a heat alarm. It can rapidly detect incremental temperature and give off warning under the condition that the environmental temperature between 54ºC-65ºC,in order to alert the dwelling of the dangerous situation and notice residents to evacuate right away. In the alarming mode, if the alarm is Wireless Interconnection with other heat detectors, other alarms will also send alarm signals.
           A DC 3V battery and warns you when the battery is low.
           In order to not disturb your rest, the product designed function of silence and no disturb.
The heat alarm should be installed in kitchen, garage and other area of the home. Making sure the people at home will be able to hear and respond to the alarm sound. Installation position should be near possible fire source.
           The test function of the product design is to test whether the product works properly by pressing
the test button. Weekly testing is required.
           This product is designed with Wireless interconnection function, it can realize Wireless Interconnection alarm.
Button Operation
               Wireless Interconnection Setup: Press the test button on the MASTER unit three times within three seconds, the alarm will receives the wireless signal, when alarm receives complete, the buzzer will beep 1 times. Or else the red LED will flash quickly, the unit is now in sending radio signal mode. This mode will last for 90 seconds.
              Product testing:Press and hold button            Alarm silence: during the alarm is alarming, push the test button.
LED &Buzzer Status
            Local alarming mode: when the heat alarm device detect the environmental temperature arrive the alarming condition, the red LED will flash once per second with pulsating alarm until the temperature declined
           
Interconnection alarming mode: when the heat alarm device detect the environmental temperature between 54ºC- 65ºC, the alarm will send local alarm signal, other interconnection alarms will send alarm signals. The wired interconnection alarms will go into interconnection alarming mode: BI - BI - pause 1.2s, with the red LED flashes, the alarm pattern is repeated
         
 Low battery mode: when the battery voltage below threshold, the red LED will flash once every 40 seconds with a sound of "chrip"
         
 Fault mode: if the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 40 seconds
         
 Silence mode: press the test button at least 2 seconds, it will go into silence mode for approx. 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds
         
 No disturb mode: when the alarm device is in low battery mode, in order to avoid disturbing you at night, please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 40 seconds during NO DISTURB MODE
           
Test mode: test the unit to ensure operate properly by pressing the test button. At this time,the red LED will flash once per second with pulsating alarm until test button is released.
         
Installation Instructions:


The heat alarm should be installed in kitchen, garage and other area of the home. Making sure the people at home will be able to hear and respond to the alarm sound. Installation position should
be near possible fire source.

BS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat AlarmBS5446 Bsi Ukca Approval Wireless Heat Detector 10 Years Battery Operated Interlinked Heat Alarm


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier