Mains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke Detector

Type: Smoke Detectors
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Smoke Alarms
Anti-Theft Alarm System-Wide: Wire Alarm Detectors
Anti-Theft Alarm System Distance: Common Detectors
Types of Smoke Detectors: Photoelectric Smoke Style
Samples:
US$ 12.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
TSS890B-HI
Infrared Sensor Probe Type
Inclination Sensor
Infrared Sensor Installation
Ceiling
Power Source
AC220V-AC240V, DC 9V Battery Backup
Size
140mm in Diameter X 44mm Depth
Certificate
CE, Bsi, Ukca, RoHS, Reach, ISO9001, BSCI
Transport Package
Carton
Specification
140mm in diameter x 44.9mm depth
Trademark
JBE
Origin
Zhejiang, China
Production Capacity
100000 Piece/Month

Product Description

 

Mains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke Detector

AC 220V main power DC 9V backup battery with wired 
interconnection photoelectric smoke alarm(wireless module optional)

 


Technical Specifications:

Power Source AC 220V-AC240V, DC 9Vbattery backup Alarm Volume >85dB(A) @ 3 meters
AC Quiescent Current < 100mA Low Voltage Threshold ≤7.5V
AC Alarm Current < 100mA Hush Time 8minutes
DC Quiescent Current < 10uA Product Service Life >10 years
DC Alarm Current < 28mA Humidity Range < 93% relative humidity (RH)
Alarm Sensitivity 0.10-0.16dB/m Temperature Range 0ºC to 40ºC
Comply With Standard EN14604:2005/AC:2008 Size 140mm in diameter x 44.9mm depth
Sound Pattern  (BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the RED LED flash, repeat this alarm pattern)
Mains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke Detector
Details of the product function:
Standby mode after the product is installed, if the smoke alarm device operate properly, the red LED flashes once every 40 seconds
Local alarming mode when the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with pulsating alarm until the smoke is disappeared
Interconnection alarming mode when the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the alarm will send local alarm signal, other interconnection alarms will send alarm signals. The wired interconnection alarms will go into interconnection alarm mode: BI - BI - pause 1.2s, with the red LED flashes, this alarm pattern is repeated
Low battery mode when the battery voltage below threshold, the red LED will flash once every 40 seconds with a sound of "chrip"
Fault mode if the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 40 seconds
Silence mode press the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds
No disturb mode when the alarm device is in low battery mode, in order to avoid disturbing you at night, please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 40 seconds during No disturb mode
Test mode test the unit to ensure proper operation by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is released
NOTE WEEKLY TESTINGIS REQUIRED.

Wireless Interconnection Set up:
>1< Select one of smoke alarms as the MASTER unit. Treat other units as SLAVE units.
>2< Press the test button on the MASTER unit three times within two seconds, the red LED will flash quickly, the unit is now in sending radio signal mode. This mode will last for 48 seconds.
>3< While the MASTER unit is in sending radio signal mode, press the test button on any SLAVE unit three times within two seconds, the SLAVE unit learns this signal and completes the pairing after a sound "beep" with light flash once
>4< Repeat the above steps on all other SLAVE units
Clear wireless connection function Press the test button on any SLAVE unit three times within two seconds, the red LED will flash quickly, then press and hold the test button again until the red light goes out the first time and release the button immediately, the red LED will flash slowly, at this time, press the test button again, the SLAVE unit will beep 3 times, which means that the SLAVE unit clears wireless connected successfully.
Mains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke DetectorMains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
>2000 square meters